BBM & YBM INSTRUCTIONS [May 2004]
Installing the Motor [Continued]
8. Connect the two white motor field winding wires to the
terminal block in the same location as the black and white
wire coming from the accessory outlet plug.
9. Push the blade guard onto the blade shaft casting housing
and then insert the two screws located at the bottom of the
blade shaft housing casting and tighten.
10. Insert a Phillips head screw driver into the blade guard
screw access holes and align the two screws holding the
blade guard on the cutting head casting and then tighten.
11. Push both blade flanges onto the end of the blade shaft.
Then using a 17mm wrench, turn the blade shaft screw
counter-clockwise and tighten the screw and washer
assembly onto the end of the shaft.
12. Insert the two plastic plugs in the blade guard to protect the
two blade guard mounting screws located under the blade
guard.
Motor replacement complete