Highland HP6IFC-2 Use And Care Manual - Page 16

Browse online or download pdf Use And Care Manual for Cooktop Highland HP6IFC-2. Highland HP6IFC-2 20 pages. Induction ceramic hob

ELECTRICAL CONNECTION

 The installation of this appliance and the connection to the electrical network should be
entrusted only to an electrician following the normal regulations.
 Protection against the parts under tension must be ensured after the building-in.
 The information on connections necessary are on the stickers. Place them on the hob
casing near the connection box.
 Connection to the mains must be made using an earthed plug, which must be accessible
after installation, or via an omnipolar circuit breaking device with a contact opening of at
least 3 mm.
 The electrical circuit must be separated from the network by adapted devices, for example:
circuit breakers, fuses or contactors.
 If the appliance is not fitted with an accessible plug, a disconnecting means must be
incorporated in the fixed installation, in accordance with the installation regulations.
 The inlet hose must be positioned so that it does not touch any of the hot parts of the hob
or oven.
Caution!
This appliance must only be connected to a 230 V~ 50/60 Hz network.
Connect the earth wire.
Respect the connection diagram.
The connection box is located underneath at the back of the hob casing. To open the cover, use
a medium screwdriver. Place it in the slits and open the cover.
CONNECTION OF THE HOB FOR HT3IFC-2
Mains
230V~ 50/60Hz
400V~ 50/60Hz
* minimum cable thermal rating: 90°C
CONNECTION OF THE HOB FOR HP4IFC-2
Mains
230V~ 50/60Hz
400V~ 50/60Hz
* calculated with the simultaneous factor following the standard EN 60 335-2-6/1990
Connection
Cable diameter
1 Phase + N
5 x 1.5 mm²
2 Phases + N
5 x 1.5 mm²
Connection
Cable diameter
1 Phase + N
3 x 2,5 mm²
2 Phases + N
4 x 1.5 mm²
Cable
H 05 V2V2 – F*
H 05 V2V2 – F*
Cable
H 05 VV - F
H 05 RR - F
H 05 VV - F
H 05 RR - F
16
Protection calibre
40 A
25 A
Protection calibre
25 A *
16 A *