2hp Rnd Manual - Page 7
Browse online or download pdf Manual for Music Equipment 2hp Rnd. 2hp Rnd 7 pages. Random voltage generator
4. AMP:
Amplitude control for the random voltage emitted from the RND OUT
If the knob is far left, random voltage will be fully attenuated (0V)
If the knob is far right, random voltage will be full scale (10V)
5. RATE CV:
Control voltage input for the rate of the internal clock
–
Range 0V
8V
Control voltage is added to the knob position
6. LED:
LED that illuminates at the rate of the internal clock when the INT/EXT toggle is in the
left position
LED that illuminates when a random gate signal is emitted from the GATE OUT when
the INT/EXT toggle is in the right position
7. GATE OUT:
Output that will emit gate signals at the rate of the internal clock when the INT/EXT
toggle is in the left position
Output that will emit random gate signals when the INT/EXT toggle is in the right
position
8. RND OUT:
Output that will emit stepped random voltage at the rate of the internal or external
clock
–
Range: 0V
10V (Max range dependent upon the AMP control)
7