Highly Components HC-60 Installation Manual - Page 2
Browse online or download pdf Installation Manual for Outdoor Light Highly Components HC-60. Highly Components HC-60 2 pages. Infrared sensor lamp
INSTALLATION:
➢
Switch off the power.
➢
Screw off the nail on the bottom of sensor lamp and unload
the bottom. Open the wire hole in the bottom and pass the
wire through the hole.
➢
Fix the bottom on the selected position with the inflated
screw.
➢
Connect the power wire into connection-wire column
according to the connection-wire diagram.
➢
Fix back the sensor lamp on the bottom. Switch on the power and then you can test it.
CONNECTION-WIRE DIAGRAM:
SENSOR INFORMATION:
Height of installation: 1.8-2.5m
TEST:
➢
Turn the LUX knob clockwise on the maximum (sun),
and turn the TIME knob anti-clockwise on the
minimum(10s)
➢
Switch on the power; the lamp will have no signal at
the beginning. After Warm-up 30sec, the lamp can
start work .If it receives the induction signal, the lamp
will turn on. While there is no another induction signal
any more, the lamp should stop working within 10sec±3sec.
➢
Turn LUX knob anti-clockwise on the minimum (3). If the ambient light is more than 3LUX,
Detection Distance: Max.12m
the lamp should not work. If the ambient light is less than 3LUX (darkness), the sensor
would work. Under no induction signal condition, the lamp should stop working within
10sec±3sec.
Note: when testing in daylight, please turn LUX knob to
the sensor lamp could not work!
NOTES:
➢
Should be installed by electrician or experienced person;
➢
Avoid installing it on the uneven object;
➢
There should be no hindrance and moving objects in front of the detection windows to
affect detection;
➢
Avoid installing it near air temperature alteration zones such as air condition, central
heating, etc;
➢
Considering your safety, please do not open the cover when you find the hitch after
installation.
If there is difference between instruction and the function the product has, please give
priority to product and sorry not to inform you additionally.
SOME PROBLEM AND SOLVED WAY:
➢
The load does not work:
a. Please check if the connection of power source and load is correct.
b. Please check if the load is good.
c. Please check if the settings of working light correspond to ambient light.
➢
The sensitivity is poor:
a. Please check if there is any hindrance in front of the detector to affect it to receive
the signals.
b. Please check if the ambient temperature is too high.
c. Please check if the induction signal source is in the detection field.
d. Please check if the installation height corresponds to the height required in the
instruction.
e. Please check if the moving orientation is correct.
➢
The sensor can not shut off the load automatically:
a. Please check if there is continual signal in the detection field.
b. Please check if the time delay is set to the maximum position
c. Please check if the power corresponds to the instruction.
(SUN) position, otherwise