3.3 Setup

After the UMR2 has been wired to the host keyboard, the UMR2 Setup Procedure must be completed.
The purposes of the setup procedure are the following:
Set the MIDI channel of the UMR2 for both MIDI input and output.
Set the MIDI note number corresponding to the lowest (leftmost) note on the host keyboard.
Allow the UMR2 to "learn" the keyswitch matrix configuration of the host keyboard.
Notes:
Once the setup procedure is completed, the UMR2 will store its settings indefinitely. However,
the procedure can be repeated as many times as needed.
By repeating only steps 1-5 of the setup procedure and disconnecting power, the UMR2 MIDI
response (channel and note range) can be changed without altering the learned matrix
configuration.

3.3.1 Setup Procedure

1. Power off the UMR2.
2. Press (close) and hold the PRGM switch.
3. Power on the UMR2. The red ACT LED will light.
4. Release (open) the PRGM switch. The green STBY LED will blink continuously.
5. Send a single MIDI note to the UMR2. This note specifies the MIDI channel setting for the
UMR2. It also specifies the note number that corresponds to the lowest note on the keyboard. To
confirm receipt of the note, the red ACT LED will light for several seconds.
6. Wait for the red ACT LED to clear. The green STBY LED will blink continuously.
7. Briefly press and release each key on the host keyboard. Start with the leftmost key and continue
in order until the rightmost key is pressed. After each keypress, wait for the red ACT LED to
blink before continuing with the next key.
8. Press (close) the PRGM switch. The red ACT LED will light while the UMR2 stores the results
of the setup procedure. When both LEDs are clear, power off the UMR2 and open or disconnect
the PRGM switch.
© 2012 Sonarcana LLC
UMR2 RevC / V1.0
Page 9 / 11