Emerson FB2100 Field Replacement Manual - Page 13

Browse online or download pdf Field Replacement Manual for Industrial Equipment Emerson FB2100. Emerson FB2100 16 pages. Flow computer i/o terminal board
Also for Emerson FB2100: Field Replacement Manual (16 pages), Field Replacement Manual (8 pages), Field Replacement Manual (14 pages), Field Replacement Manual (16 pages)

Emerson FB2100 Field Replacement Manual
FB2100/FB2200 Flow Computer I/O Termination Board Field Replacement Guide
2.
Remove power by unplugging terminal block TB2 (pins 1,3,5,7).
3.
For the terminal block you want to replace, make sure you note which wire goes to which
terminal. If they aren't labeled, you should label them or take a digital photo so you know
which wire goes to which connector of the terminal block.
4.
Use a flat head screwdriver to loosen the screw for each wire coming into the old terminal
block. Slide the same wire into the identical position on the new (replacement) terminal
block and tighten the screw to hold it in place. Repeat for each wire.
5.
Repeat steps 3 through 4 for each terminal block you want to replace.
D301805X012
November 2020
11