Emerson FB2100 Field Replacement Manual - Page 5
Browse online or download pdf Field Replacement Manual for Industrial Equipment Emerson FB2100. Emerson FB2100 16 pages. Flow computer i/o terminal board
Also for Emerson FB2100: Field Replacement Manual (16 pages), Field Replacement Manual (8 pages), Field Replacement Manual (14 pages), Field Replacement Manual (16 pages)
FB2100/FB2200 Flow Computer I/O Termination Board Field Replacement Guide
2.
Remove power by unplugging terminal block TB2 (pins 1,3,5,7).
3.
Disconnect the intermediate cable between the CPU enclosure and the sensor module. To
do this, press down on the outer edge of the connection tab, then pull the connectors apart.
4.
Use a #2 Phillips-head screwdriver to loosen the four captive fastening screws that hold the
CPU enclosure and gently pull the assembly (including the HMI module) out and set it aside.
D301805X012
November 2020
3