Emerson FB1100 Field Replacement Manual - Page 5

Browse online or download pdf Field Replacement Manual for Accessories Emerson FB1100. Emerson FB1100 8 pages. Flow computer coin cell battery field
Also for Emerson FB1100: Termination Board Field Replacement Manual (18 pages), Replacement Manual (18 pages), Field Replacement Manual (14 pages), Field Replacement Manual (20 pages), Field Replacement Manual (8 pages), Replacement Manual (8 pages)

Emerson FB1100 Field Replacement Manual
FB1100/FB1200 Flow Computer HMI Module Field Replacement Guide
Components of Retaining Clamp Assembly
1
Screw
2
Retaining Clamp
3
Washer
2.
Grasp the end cap (front or rear).
Front End Cap
3.
Unscrew the end cap turning it counter-clockwise until the cover comes off. Set it aside in a
safe location.
Note
If you need more leverage place a long screwdriver or other appropriate tool across the two
notches in the cover to act as a pry bar.
Front End Cap (unscrewed)
Important
When replacing the rear end cap, ensure wires connecting to the terminal plate do not get
crimped or caught between the end cap threads and the enclosure.
4.
With a #1 Phillips-head screwdriver, loosen the four captive fastening screws on the HMI
module.
Rear End Caps
D301816X012
November 2020