Emerson FB1200 Field Replacement Manual - Page 9

Browse online or download pdf Field Replacement Manual for Accessories Emerson FB1200. Emerson FB1200 20 pages. Flow computer coin cell battery field
Also for Emerson FB1200: Termination Board Field Replacement Manual (18 pages), Replacement Manual (18 pages), Field Replacement Manual (14 pages), Field Replacement Manual (8 pages), Field Replacement Manual (8 pages), Replacement Manual (8 pages)

Emerson FB1200 Field Replacement Manual
FB1100/FB1200 Flow Computer Sensor Assembly Field Replacement Guide
Removing/Replacing the Sensor Assembly
UL Listed Sensory Assembly Field Installed Accessory Kits for Use in Class I, Division 1, Groups C
and D, Class I, Division 2, Groups A, B, C, D. See Table 1 (for FB1100) or Table 2 (for FB1200) to
determine correct UL Listed kit numbers.
Note
The removal/replacement procedure is the same for all sensor assemblies listed in this guide.
To replace the sensor assembly, you first need to remove the battery enclosure/HMI module
assembly, the I/O termination board, and the CPU module.
1.
Remove the front and rear end caps. Remove the retaining clamps on the end caps (if
present) using a 3 mm hexagonal wrench.
Components of Retaining Clamp Assembly
1
2
3
2.
Grasp the end cap.
Front End Cap
Screw
Retaining Clamp
Washer
Rear End Cap
D301842X012
November 2020
3