Section 363-765-100
Revision 01
TABLE 4. RT ENCLOSURE CONNECTORS (TEST & CONFIGURATION)
Connector
ID_0 GND
ID_1 GND
ID_2 GND
TEST_IN_TIP
TEST_IN_RING
TEST_OUT_TIP
TEST_OUT_RIN
G
BYPASS_T
BYPASS_R
SSC1_A
SSC1_B
SSC2_A
SSC2_B
Connector
HDSL_1_T
HDSL_1_R
HDSL_2_T
HDSL_2_R
PWR_1_T
PWR_2_R
PWR_2_T
PWR_2_R
Connector
-48V
GND
CHASSIS GND
Note:
CO Ground is separate from Chassis Ground in PG-Flex. Technicians can
connect them on the RT Backplane by connecting the "CHASSIS GND" wire-wrap post to
the adjacent "GND" wire-wrap post.
Page 6
Type
0.45 mm
(No Connection - Future)
Wire Wrap
0.45 mm
(No Connection - Future)
Wire Wrap
0.45 mm
(No Connection - Future)
Wire Wrap
0.45 mm
Test connection looking into the RT channel unit for the selected
Wire Wrap
subscriber. This connection must be set up through the PG-Flex
RS-232 maintenance port.
0.45 mm
Test connection looking into the drop of the selected subscriber.
Wire Wrap
This connection must be set up through the PG-Flex RS-232
maintenance port.
0.45 mm
Termination for the metallic bypass pair to the COT.
Wire Wrap
0.45 mm
Special Signaling Channel #1. A user-definable input (through the
Wire Wrap
RS-232 Maintenance Port at the COT) that produces an alarm at
the COT based on a condition at the RT. This requires a contact
closure between SSC1_A and SSC1_B.
0.45 mm
Special Signaling Channel #2. A user-definable input (through the
Wire Wrap
RS-232 Maintenance Port at the COT) that produces an alarm at
the COT based on a condition at the RT. This requires a contact
closure between SSC2_A and SSC2_B.
TABLE 5. RT ENCLOSURE CONNECTORS (HDSL)
Type
Function
AMP
Tip and ring terminations for HDSL Pair #1 of System #1 from the
Quiet
COT. +130 V dc is simplexed on this line for powering the RT.
™
Front
AMP
Tip and ring terminations for HDSL Pair #2 of System #1 from the
Quiet
COT. -130 V dc is simplexed on this line for powering the RT.
™
Front
AMP
(No Connection - Future)
Quiet
™
Front
AMP
(No Connection - Future)
Quiet
™
Front
TABLE 6. RT ENCLOSURE CONNECTORS (LOCAL POWER)
Type
Screw
CO Battery (-48 V dc)
Screw
CO Ground
Screw
Chassis Ground
Function