Galvin Specialised Ezy-Drink TD45C Product Installation Manualline

Browse online or download pdf Product Installation Manualline for Plumbing Product Galvin Specialised Ezy-Drink TD45C. Galvin Specialised Ezy-Drink TD45C 4 pages. Remote bubbler tapware

®
Ezy-Drink
Remote Bubbler Tapware
PRODUCT CODES:
- TD45C
- TD90C
SPECIFICATIONS
Drinking taps are designed to operate at full mains pressure.
Rubber and metal mouthguards are designed to help protect teeth when drinking.
Rubber mouthguard is resistant to fungal and bacterial attack and has a high resistance to sunlight.
Vandal resistant handle.
Adjustable built-in flow restrictor.
IMPORTANT: All Ezy-Drink
premises in good working order.
TECHNICAL DATA
Inlet
Outlet
Headwork
Working Pressure Range (kPa)
Maximum Working Temperature (°C)
Nominal Flow Rate (LPM)
Finish
NOTE: Galvin Specialised continually strive to improve their products. Specifications may change without notice.
PRE-INSTALLATION
MOUNTING DETAILS – HOLE CENTRES
TD90C - If the mounting holes do not already exist, mark
out and drill the holes in the wall/sheet, as shown in
rough-in dimensions.
Note: Before installation, all lines must be flushed. We
recommend that a line strainer be installed prior to drinking taps
to eliminate any foreign material.
TOOLS REQUIRED
Power drill
Spanner or adjustable crescent
Screw driver
®
Remote Bubbler taps are tested in accordance with AS/NZS 3718 and leave our
Version 1, 31 October 2016, Page 1 of 4
15BSP - Female
Rubber / metal mouth guard
Cam Action
Min
50
Max
500
Min
5
Max
70
4.5
Chrome
50.5
TO SUIT
SCREWS
USED