Galvin Specialised Ezy-Wash TF85-C Product Installation Manual - Page 3
Browse online or download pdf Product Installation Manual for Kitchen & Bath Fixtures Galvin Specialised Ezy-Wash TF85-C. Galvin Specialised Ezy-Wash TF85-C 5 pages. Pre-rinse tapware
Retro-Fit {Installation to existing Galvin Specialised Ezy-Wash Pre-Rinse unit (the unit will need to be isolated
at the control valves)}
1. Disassemble wall bracket
Unscrew the compression nut from the wall
flange using two spanners (1
wall flange, 2
for the compression nut).
nd
Pull out support rod from wall flange and
loosen the support rod from upper riser hook
(if required).
3. Fit pot filler and riser
Remove protective cap from upper riser
spindle
Fit the upper riser to the lower riser,
ensure the sealing o-rings are inside the
spindle
Tighten with new supplied grub screw.
It is critical that the grub screw point
locates accurately into hole recess of
mating part. Failure to do so may result
in damage and/or failure of the unit.
2. Disassemble pre-rinse riser
st
to support the
4. Fit pre-rinse riser assembly
Version 2, 4 August 2017, Page 3 of 5
Unscrew grub screw from top riser
assembly.
Separate top riser, paying special
attention to not damage any o-rings.
Remove pre-rinse unit body from hub
mounted assembly (if required).
Screw support rod into the riser hook and
ensure it is not fully tightened (if applicable).
Fit compression nut to support rod,
followed by the compression cone and
locate the support rod into wall bracket.
Fit the pre-rinse riser assembly through the
drilled hole on the bench and secure.