Board Overview

Wiring

GAS VALVE
A gas solenoid valve should be powered using the terminals marked [VALVE OUT].
When the valve out terminal is wired to a normally closed (NC) gas solenoid valve, the device can be used
to isolate the gas supply for multiple appliances.
Use an external transformer (not supplied) to close a 24VAC gas solenoid valve that could supply gas to
one or more appliances.
Gas Supply Controlled by 100-120VAC Solenoid Valve
We do not recommend installing a gas solenoid valve with standing pilots!
If you use a gas solenoid valve, please note that standing pilots will need to be re-lit!
Rev: 20 12-20
Gas Supply Controlled by 24VAC Solenoid Valve