Main Combi 30 HE User Manual - Page 3

Browse online or download pdf User Manual for Boiler Main Combi 30 HE. Main Combi 30 HE 12 pages. Main gas heater

Main Combi 30 HE User Manual
ON/OFF/Reset
Indicator
Selector Switch
Neons
Reset
OFF Position
The boiler will not operate.
Indicator
Neons
2
1
3
0
4
bar
© Baxi Heating UK Ltd 2009
Central Heating
Temperature Control
Reset
Central Heating & Hot Water
Both Heating & Hot Water will operate.
Power On Indicator - The indicator will illuminate when there is power to the
boiler.
Domestic Hot Water Indicator - The indicator will illuminate when hot water
is being supplied to a tap or shower.
Boiler On - The indicator will illuminate when there is a demand for heat to
the boiler.
Burner On Indicator - The indicator will illuminate when the burner has fired
and is heating your central heating or domestic hot water.
Central Heating Temperature Control
Turn the knob clockwise to increase or anticlockwise to decrease the
temperature. Range 35 - 85° C.
Domestic Hot Water Temperature Control
Turn the knob clockwise to increase or anticlockwise to decrease the
temperature. Range 35 - 65° C.
Central Heating System Pressure - The normal operating water pressure is
between 1 and 2.0 bar. If the pressure exceeds 3 bar the safety pressure valve
will operate and a fault is indicated. Contact your Installer.

1.0 Quick Reference Guide

Domestic Hot Water
Temperature Control
Reset
Domestic Hot Water
Hot Water will operate.
2
1
3
0
4
bar
System Pressure Gauge
Optional Timer
Reset
Reset
Hold for approx 5 seconds and release.
Position of
3