Output Current Sensing: The current sensing circuit will monitor the output current and turn off the output and reset the output
for 5-seconds when the output current exceeds the current trip setting of the switch. The output current sensing is adjustable
from 5-Amperes to 35-Amperes. There is a 0.5-second delay in the current sensing to allow for motor inrush.

SWITCH SETTING

CURRENT LIMIT

0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Current Sensing Instructions
5 AMPS
7 AMPS
9 AMPS
11 AMPS
13 AMPS
15 AMPS
17 AMPS
19 AMPS
21 AMPS
23 AMPS
25 AMPS
27 AMPS
29 AMPS
31 AMPS
33 AMPS
35 AMPS
CURRENT SENSING ROTARY SWITCH
RF12V1PR-LS
Instruction Manual
The recess down
the length of the shaft
points to the setting
0
E F
D
C
B
A
9
8
Page 5 REV A 03/09/20