Corbin Russwin ASSA ABLOY Access800 Installation Instructions Manual - Page 19
Browse online or download pdf Installation Instructions Manual for Locks Corbin Russwin ASSA ABLOY Access800. Corbin Russwin ASSA ABLOY Access800 20 pages. For ml20800 tcac2 series mortise lockset
7) ML20800 TCAC2 Hardwiring Instructions
7.7) M35 Power/Remote Unlocking with M861 Propped Door, Forced Door
NOTE:
M861 Harnesses are
Illustrated on page 14
Specific connections
are defined on page 15.
784
+9 VDC
9VDC
Power Supply
EGND
120 VAC L/N/G
Normally Open
momentary switch
(Remote unlock
- REX option)
NO
C
Black, 1
Red, 2
White, 3
Green, 4
Orange, 5
Blue, 6
Brown, 7
Yellow, 8
C
*NC
DPS Switch
*Wire for switch
contact closure
White, 3
when door is opened.
Green, 4
Typical locations
shown in Fig. 1
with 8 and 4-pin connectors,
12 wires and pigtail harness
Installation:
®
1.
ElectroLynx System Wiring Instructions (refer to Fig. 1 and Fig. 4)
a. Look for the mating part on ASSA ABLOY doors and frames. Then plug in all connectors as shown
in Fig. 4 during product installation.
b. Hard wire forced/propped, hard power and/or remote unlock (REX) as shown.
2.
Non-ElectroLynx System Wiring Instructions (refer to Fig. 1 and Fig. 4)
a.
Cut the 8-pin connector off the Power/Remote Unlock harness and hard wire to non-ElectroLynx
door harness. Remote power requires three conductors and remote unlock requires two conductors.
b. Hard wire door harness to power transfer device.
c. Hard wire forced/propped, hard power and/or remote unlock (REX), as shown.
Door
Outside
Escutcheon
-9 VDC
Power/Remote Unlocking
Forced Door, Propped Door
ElectroLynx Wiring System
Red, 1
Black, 2
QC12 Electric Hinge
®
END OF INSTALLATION INSTRUCTIONS
6 AA batteries MUST be removed from
controller if 784 Power supply is used.
Inside
Escutcheon
Controller
Fig. 4
®
®
ElectroLynx Door Harness
with 8 & 4-pin connectors.
Harness location is
dependent on door type.
19
ASSA ABLOY
Ground Tab
Remote Power and
REX Connector TB2
Motor
Connector
TB1
1 2 3 4 5 6 7 8
M35
Power/Remote
Unlocking
Harness
3 2 1
REX Input
Connect to
4
Device
Tan
3
Pink
M861 Forced
Door,
Propped Door
Harness
4-pin
connector
ElectroLynx® is a registered trademark of ASSA ABLOY Inc.
Copyright © 2014 Corbin Russwin, Inc. All rights reserved.
Reproduction in whole or in part without the express written
permission of Corbin Russwin, Inc. is prohibited.
®
®