7) Hard Wiring Instructions
7.4)
M861 Quick Code, Forced Door Propped Door Option.
Fig. 1
B
A
B
1
2
4
5
7
8
*
0
C
B
(Exit Device Escutcheons Shown)
C
*NC
D
DPS Switch
*Wire for switch
contact closure
when door is
opened. Typical
locations shown
in Fig. 1
Installation:
1. ElectroLynx™ System Wiring Instructions (refer to Fig. 1 and Fig. 2)
a. Look for the mating part on ASSA ABLOY doors and frames. Then plug in all
connectors as shown in Fig. 2 during product installation.
b. Hard wire DPS switch as shown.
2. Non-ElectroLynx™ System Wiring Instructions (refer to Fig. 1 and Fig. 2)
a. Cut the 4-pin connector off the Forced Door Propped Door harness and hard wire
to ElectroLynx™ two conductor door harness.
b. Hard wire door harness to power transfer device.
c. Hard wire DPS switch to power transfer device.
Door
D
C
3
6
9
#
Outside
Escutcheon
Forced Door/Propped Door Option
ElectroLynx™ Wiring System
Red, 1
Black, 2
White, 3
Green, 4
A
QC4A Electric Hinge
with 4-pin connectors,
and pigtail harness
Inside Escutcheon
Controller
DPS Connector
used for M861
Option
Fig. 2
B
ElectroLynx Door
Harness with
8 & 4-pin
connectors.
Harness location
is dependent on
door type.
13
REX Connector
Ground Tab
TB2
Motor
Connector
TB1
1 2
3 4
3 2 1
4
connector,
Tan
connect to
3
Pink
connector
M861 Forced
Door,
(See page 3)
Propped Door
Harness
4-pin
connector
5 6
7 8
REX
the
coming
from the
device.