Corbin Russwin 615F60 Installation Instructions - Page 4

Browse online or download pdf Installation Instructions for Door Opening System Corbin Russwin 615F60. Corbin Russwin 615F60 5 pages. Multi-sized 1 thru 6/half-size 1 thru 6, universal door closers with heavy duty spring stop parallel arms

Corbin Russwin 615F60 Installation Instructions
Installation Instructions
Installation Instructions
Parallel Arm Application A11 or A12 Arm
4. Connect Arm To Closer
Using hex wrench provided, close (turn clockwise) CLOSING SPEED VALVE (see page 4 for
location on closer). DO NOT OVER TIGHTEN.
Open door to approximately 60°
Using wrench on underside of spindle, rotate spindle
approximately 135° toward hinge edge of door.
Install arm on spindle at an approximate 90° angle to door.
Reopen CLOSING SPEED VALVE.
Install and tighten arm washer and screw.
Rotate 135°
SPINDLE
SPINDLE AT REST
Hold Open
Hold Open
80-9360-6003-152 Rev. 12/06
ALL ANGLES SHOWN ARE APPROXIMATE
CENTERLINE
SPINDLE
ROTATED 135°
HOLD OPEN ADJUSTMENTS - A12 ARMS ONLY
"On"
Hold Open Force
"Off"
90°
ARM
To Decrease
Hold Open
Force
90°
ARM
WRENCH
Rotate
To Increase
Hold Open
Force
60°
DOOR
135°
Page 4