Recommended separat ion d istances between
Portable and mobile RF communicat ions equipment and device
The device is intended for use in an electromagnetic environment
in which radiated RF disturbances are controlled. The customer
or the user of the device can help prevent electromagnetic
interference by maintaining a minimum distance between portable
and mobile RF communications equipment (transmitters) and the
device as recommended below, according to the maximum output
power of the communications equipment.
Separat ion d istance accord ing to frequency of
Rated maximum
output power of
transmit ter
150 kHz to 80
W
MHz
d = 1,2√p
0.01
0.12
0.1
0.38
1
1.2
10
3.8
100
12
For transmitters rated at a maximum output power not listed
above, the recommended separation distance d in meters (m)
can be estimated using the equation applicable to the frequency
of the transmitter.Where p is the maximum output power rating
of the transmitter in watts (W) according to the transmitter
manufacturer.
Note 1: At 80 MHz and 800 MHz, the separation distance for the
higher frequency range applies. Note 2: These guidelines may not
apply in all situations. Electromagnetic propagation is effected by
absorption and reflection from structures, objects and people.
For support, please contact at +1-650-397-6103 or visit www.dynosense.com
All manuals and user guides at all-guides.com
transmit ter
m
80 MHz to
800 MHz to
800 MHz
2.5 GHz
d = 1,2√p
d = 2,3√p
0.12
0.23
0.38
0.73
1.2
2.3
3.8
7.3
12
23
Symbol
IPX4
+40℃
(+104
)
+10℃
(+50
)
1060hPa
800hPa
95%
10%
22
For support, please contact at +1-650-397-6103 or visit www.dynosense.com
Title
Protected against splashing water
Operating, storage and transport temperature
limit
Operating, storage and transport atmospheric
pressure limitation
Operating, storage and transport humidity
limitation
Operating instruction
Follow operating instruction
Non-ionizing radiation
Type BF applied part
No Alar ms
Manufacturer
Do not dispose this product as unsorted
municipal waste
Recycle
Underwriters Laboratories
MEDICAL — PATIENT MONITORING EQUIPMENT
AS TO ELECTRICAL SHOCK, FIRE AND
MECHANICAL HAZARDS ONLY IN ACCORDANCE
WITH IEC 60601-1 (2012), "Medical Electrical
Equipment - Part 1: General Requirements for
Basic Safety and Essential Perfor mance;
CSA-C22.2 No. 60601-1:08
CE Marking
MR unsafe, presents hazards in all MR
environments as device contains strongly
ferromagnetic materials.
Prescription ONLY.