Cordes CC-5RS Instruction Manual

Browse online or download pdf Instruction Manual for Smoke Alarm Cordes CC-5RS. Cordes CC-5RS 2 pages. Photo-electric smoke alarm

Cordes CC-5RS Instruction Manual
INST LLING THE SMOKE L RM
This smoke alarm is powered by a battery
and requires no additional wiring.
Having established the mounting location
ensure that there in no electrical wiring or
pipe work in the area adjacent to the
mounting surface.
Take the mounting bracket and mark the
two mounting hole locations.
Drill holes in the positions marked.
Insert wall plugs into the drilled holes.
Screw mounting bracket to mounting
surface.
DO NOT OVER TIGHTEN.
Insert a 9V battery firmly into battery com-
partment on the rear of the detector.
NOTE POLARITY OF CONNECTIONS.
Ensure the metal tab is fully depressed
when the battery has been fitted.
NOTE – For the safety of the end user the
smoke alarm cannot be fitted without its
battery.
Assemble detector onto the mounting plate
by aligning the two projections on the
WHERE TO PLACE SMOKE ALARMS
WASHING
BASEMENT
HOBBYROOM
STOREROOM
UPST.
W.C.
basement
ground floor
BEDROOM
BEDROOM
FOYER
PARENTS
W.C.
BEDROOM
top floor
mounting plate with the two keyhole slots
in the detector. Lock in position by giving a
clockwise quarter turn.
Test the correct operation of the smoke
detector by depressing the test button on
the front of the detector. The unit should
emit a loud pulsating alarm.
OPER TING YOUR SMOKE L RM
Once the smoke alarm has been installed
a small indicator light (LED), positioned
under the test button, should flash approxi-
mately once a minute in normal operation.
If smoke is detected the unit will emit a
load pulsating alarm until the air is clear.
TESTING YOUR SMOKE L RM
It is recommended that you test your
smoke alarm once a week to ensure the
detector is working correctly.
Push and hold the test button for approxi-
mately 3 seconds. A loud pulsating alarm
should sound to indicate the correct
function. During the alarm condition the
indicator light will flash quickly.
LIVINGROOM
KITCHEN
DINING-ROOM
LIVINGROOM
DOWNST.
W.C.
GARAGE
Fire extinguisher
Photo-electric smoke alarm
Minimum protection
Best possible protection
Main escape way
Beside escape way
PHOTO-ELECTRIC
SMOKE L RM
instruction manual
MODEL CC-5RS
Built-in Hush or Silence feature
SPECIFICATION:
Certificate:
Measure:
Horn Level:
Ambient Humidity:
Weight:
Operation Temperature:
Approved to:
Power Source:
G207142
EN14604 2005
GERMANY – HAMBURG
VdS/EN 14604
9,9 x 3,8 cm
85 db(A) 3m
10% - 90%
120 g
+ 4° - + 50°
VdS standard
1 x 9V-blockbattery
(brand quality)
EN
14604