Step 3: Install the Indicator (4) on the bracket,
with the bracket aligning with the bracket slot
(8) of the indicator.
Step 4: After connecting load cell connector to load cell port, the installation is completed.
Note: Use the knob pole (7) to adjust the inclination angle of indicator and the screw (6) to adjust
direction of the indicator. After adjusting the indicator to an optimal position, lock the screw.
5. Setting Mode
5-1 Maximum Weighing Capacity & Division Setting
1. Press and hold key
displays "CAP"
,
MR/
2. Press
or
"accura" — resolution check.
3. When the window is showing "CAP", press
Method1: Press
to save and return.
→
UNIT
M-/SET
and
release the key and it enters the capacity & division setting
to shift among "CAP" — capacity setting; "DIV"— division setting;
TARE/
MR/
TARE/
or
→
while powering on the scale. When the window
M-/SET
to enter capacity setting.
to choose the general used capacity. Press
JWI-700D/700S
M+/SAVE
7