Humidifier pump error
If a HUMIDIFIER PUMP ERROR displays on the touchscreen remote:
1.
Check the clear hose that connects the large reservoir to the small top
reservoir to make sure the hose is tightly connected on both ends.
2.
In large water tank, remove small round water filter.
3.
Remove piezo cleaning brush from holder (white handled brush) and gently
swish around inside the hole to clean and remove debris.
4.
Replace small round water filter.
Water tank low
If a WATER TANK LOW ERROR displays on the touchscreen remote:
1.
Fill tank with tap water to MAX FILL LINE using the water pitcher.
Note: Please contact