5. Replacing a carbon brush (Fig. 5)
<Disassembly>
(1) Loosen the D4 tapping screw retaining the tail cover and
remove the tail cover.
(2) Use the auxiliary hexagonal wrench or small screwdriver
to pull up the edge of the spring that is holding down the
carbon brush. Remove the edge of the spring toward the
outside of the brush holder.
(3) Remove the end of the pig-tail on the carbon brush from
the terminal section of brush holder and then remove the
carbon brush from the brush holder.
<Assembly>
(1) Insert the end of the pig-tail of the carbon brush in the
terminal section of brush holder.
(2) Insert the carbon brush in the brush holder.
(3) Use the auxiliary hexagonal wrench or small screwdriver
to return the edge of the spring to the head of the carbon
brush.
NOTE:
Make sure the end of the spring is not holding the pig-tail.
(4) Mount the tail cover and tighten the D4 tapping screw.
6. Service parts list
CAUTION
Repair, modifi cation and inspection of HiKOKI Power
Tools must be carried out by a HiKOKI Authorized
Service Center.
This Parts List will be helpful if presented with the tool to
the HiKOKI Authorized Service Center when requesting
repair or other maintenance.
In the operation and maintenance of power tools, the
safety regulations and standards prescribed in each
country must be observed.
MODIFICATIONS
HiKOKI Power Tools are constantly being improved
and modifi ed to incorporate the latest technological
advancements.
Accordingly, some parts may be changed without prior
notice.
NOTE
Due to HiKOKI's continuing program of research and
development, the specifi cations herein are subject to
change without prior notice.
14