3.3 Installation and dimensions

Even though the device has very compact dimen-
sions, it is strongly recommended to use the dee-
pest junction boxes possible.
Depending on which pushbutton attachments are
used, up to 30 mm of additional installation space
is required.
For installation in cavity or switch boxes, the side
flaps have to be removed. Install the device with
the labeling, LED and device buttons facing for-
wards.
30 mm
55 mm
removeable flaps