Dean Stoves 105SE Operating Instructions Manual - Page 8
Browse online or download pdf Operating Instructions Manual for Stove Dean Stoves 105SE. Dean Stoves 105SE 16 pages. Inset
The 105Se Inset stove can be flued from its angled top outlet.
The 105Se inset must be installed with a flue liner.
These stoves are not suitable to be used in a flue-shared situation.
The chimney must be sound and not too large in section. If not sound or too large, a liner will
have to be fitted; Stainless steel or ceramic liner suitable for solid fuel.
If the chimney draw is too high a flue stabilizer will have to be installed. When the chimney is
warm the draw should not be lower than 0.10 water gauge.
All appliances have been tested at 12 PA with the doors closed.
Insulating around the body of the stove on installation will help prevent heat loss into the
fabric of the chimney and heat loss up the chimney. By doing this more heat will convect
into the room.
Hearth and Surround
The stove must stand on non-flammable material at least 12mm thick (1/2"). The hearth must
extend at least 225mm in front of the firebox and 150mm to the sides. It is recommended that a
larger hearth size is fitted if possible.
The stove is designed to fit into a non-combustible chimney opening. If a combustible mantel
piece is to be fitted to the fireplace it must be at least 400mm above the top of the stove and
200mm at the sides, these are minimum distances.
The appliance must be installed on a floor with an adequate low bearing capacity.
If the construction doesn't meet the existing pre-requisite the floor must be reinforced and a
load distributing plate could be fitted.
Flue Connections and Outlets
105Se Inset stove can be flued from its angled top outlet
The 105Se inset model has a 125mm outlet and will need to be stepped up to a 150mm (6")
flue liner from the spigot unless the DEFRA stop is installed. The 105Se inset comes as
standard with the DEFRA stop fitted, if the DEFRA stop is left in place then a 125mm
liner/flue system can be installed. The installation of a flue liner is strongly recommended.
8