Adexa 6G-TRH60 Installation And Operation Instruction Manual - Page 17

Browse online or download pdf Installation And Operation Instruction Manual for Grill Adexa 6G-TRH60. Adexa 6G-TRH60 20 pages. Gas lava rock grill

Trouble Shooting

This section provides an easy reference guide to the more common problems that may occur during the
operation of your equipment. The fault finding guide in this section is intended to help you correct, or at
least accurately diagnose problems with your equipment.
Although this section covers the most common problems reported, you may encounter a problem not
covered in this section. In such instances, please contact your local authorized service agent who will
make every effort to help you identify and resolve the problem. Please note that the service agent will
require the following information:
• Model Code and the Serial Number of the appliance. (Both of them can be found on the Rating
Plate located on the appliance).
Fault
Main burner will not light.
No spark flame on main burner
Yellow flame and black smoke
The problems mentioned above are only for reference. If any fault occurs, please stop using, and contact
technicians to check and repair. Safety first, turn off the power and gas supply before maintenance.
NOTE: Components having adjustments protected by the manufacturer are only to be adjusted by an
authorized service agent. They are not to be adjusted by an unauthorized service person.
Possible Cause
Insufficient gas pressure
in pipe
No gas supply.
Nozzle occlusion
Thermocouple connection
loose
Thermocouple damage
Gas control valve failure
Faulty battery for
electronic pulse ignition
device
Faulty electronic pulse
ignition device
Use the gas of bottom
Not match nozzle
diameter with gas
resources
Not enough air to ignite
In the peak of using
gas, sources of gas float
heavy
Remedy
Contact the local gas supply dept.
Ensure gas isolation valve
is turned on, and that
bottles are not empty.
Call the service provider. .
Dredge nozzle
Tighten thermocouple
Replace thermocouple
Replace control valve
Put No 7 battery into
ignition device
Replace electronic pulse
ignition device
Replace gas
Adjust nozzle diameter
Increase damper opening
degree
Turn down valves flow.
the peak
Turn it up after
- 15 -