Maiwe MISCOM7220G-4GF-16GT User Manual - Page 4
Browse online or download pdf User Manual for Switch Maiwe MISCOM7220G-4GF-16GT. Maiwe MISCOM7220G-4GF-16GT 6 pages. Industrial ethernet switch
On
1000M working state
1000M
(Yellow)
Off
10/100M working status
The port has established a valid network
On
connection
Link/Act
Flashing
There is network activity on the port
(Green)
No valid network connection is established on
Off
the port
Hardware Installation
4
Installation Precautions
To prevent equipment damage or personal injury caused by improper use,
observe the following precautions:
During the installation process, you need to wear anti-static gloves or anti-
static gloves, and power-off the switch.
Please make sure that the input voltage is within the input voltage range
marked on the switch.
The transmission distance has a certain relationship with the connected
wire. It is recommended to use a standard Cat5e/6 network cable.
The equipment must be grounded for lightning protection, otherwise the
protection level of the equipment will be greatly reduced; please use a
wire of No.20 or more to connect the grounding terminal to the ground.
The power line, ground line and signal line are laid out separately and the
distance is not less than 5cm.
[Device installation]
Tilt the switch upwards so that the upper end of the buckle is fastened to
the upper end of the DIN rail.
The lower end of the back buckle is buckled into the DIN rail.
[Device connection]
Connect the network cable to the port in the correct direction.