Maiwe MISCOM8028G-4GF-8GC-16GT User Manual - Page 3
Browse online or download pdf User Manual for Switch Maiwe MISCOM8028G-4GF-8GC-16GT. Maiwe MISCOM8028G-4GF-8GC-16GT 7 pages. Industrial ethernet switch
Number
1
Alarm relay output normally open
2
Alarm relay output common terminal
3
Alarm relay output normally closed
[Connect the CONSOLE port]
The network management port is an RJ45 port, please use the serial port
cable of our company to connect to the serial port of the PC. The interface
communication standard is 3-wire RS232.
The communication parameters of the serial port are as follows:
Baud rate: 9600, data bit: 8, parity bit: None, Stop bit: 1, flow control: None.
The switch indicator lights description is shown in the table below:
Indicator
Status
lights
System Status LED
On
The power is connected and operating normally
PWR1/PWR2
The power is not connected or the system is
Off
not operating normally
Flashing
The system is operating normally
RUN
On/Off
The system is not working properly
ALM
On
Device power failure alarm, port offline alarm,
Pin definition
Definition
network storm alarm
Off
Device no alarm
Fiber Port Status LED
The port has established a valid network
On
connection
X1-X4
Flashing
There is network activity on the port
No valid network connection is established on
Off
the port
RJ45 Port Status LED
Each RJ45 port has two indicator lights, the yellow light is the port plastic
rate indicator, the green light is the port connection status indicator.
On
1000M working state
1000M
(Yellow)
Off
10/100M working status
The port has established a valid network
On
connection
Link/Act
Flashing
There is network activity on the port
(Green)
No valid network connection is established on
Off
the port
[Installation Size]