P 8
Replace anolyte and catholyte tubes
Remove the existing Anolyte and Catholyte tubes
and then make sure that any excess moisture is
cleaned.
Connect one of the tubes from the Flow wash kit
from the Anolyte connection on the Flow device.
Connect the other end of this tube to the 'Connect
to Anolyte' labelled input. Make sure that both
ends of the pipe are correctly xed, and the pipes
are secure.
Connect another tube from the Flow wash system
into the Catholyte connection on the Flow device
Connect the other side of this tube to the 'Catholy-
te out' connection on the Flow wash device.
Make sure that both ends of the tube are xed
correctly.
CENTREGO FLOW 40
Rinse cell using water
With the Flow wash system still in place ll the Flow
wash system tank with clean water. This water must
be fresh and clean from a drinking water tap. En-
sure that there are no particulates or oating pieces
in this water.
Turn the system on at the inline power switch to let
the system rinse with fresh water for 10 minutes.
Dispose of water that has been used for rinsing the
system out into a domestic sink. You may need to
use a bucket as the system will still be connected to
the device.
Once this is complete, remove the Flow ush
device and replace all original system pipe connec-
tions. Turn the device on by releasing the 'E-STOP'
and run the system for 10 minutes to ensure all
pipes are fully connected and no moisture leaks
due to disconnected pipes, before closing the door.
CENTREGO FLOW 40