Afore HNS3000TL User Manual Installation - Page 13
Browse online or download pdf User Manual Installation for Inverter Afore HNS3000TL. Afore HNS3000TL 17 pages. Pv inverter single mppt
Insert striped cable into contact barrel and insure all conductor strands are
2.
captured in the contact barrel.
Compress them together with the crimping pliers.
3.
Insert contact cable assembly into back of male and female connector. A "click"
4.
should be heard or felt when the contact cable assembly is seated correctly. Then
turn the cap to the coupler. Please refer to the following figures.
5.3.3 Connecting the PV Generator (DC)
DANGER!
Danger to life due to high voltages in the inverter.
• Before connecting the PV generator, ensure that the AC&DC circuit breaker is
switched off and that it cannot be reactivated.
Notes:
1. Disconnect the circuit breaker.
2. Check the connection cables of the PV modules for correct polarity and that the
maximum input voltage of the inverter is not exceeded.
3. Check the DC plug connector for correct polarity and connect it.
Plug the DC plug connector to DC terminal on inverter.
11 / 15