Bristan COB SHC3STP C (D9) Installation Instructions & User Manual - Page 2

Browse online or download pdf Installation Instructions & User Manual for Plumbing Product Bristan COB SHC3STP C (D9). Bristan COB SHC3STP C (D9) 2 pages.

General Cleaning
Bristan products are made from premium materials, with
hand polishing and electroplated finishes.
Your taps or shower should be regularly cleaned with warm
water, a mild pH-neutral liquid soap, and polished with a soft
cloth. Any residues from soap, toiletries etc. should be rinsed
off straight after use.
Household bleaches and cleaners contain harsh chemicals and
may damage the surface finish. Avoid using abrasive cloths,
scouring pads, scrub sponges, steel wool or anything similar.
Some surfaces such as nickel and pewter may be affected by
the dye found in some cloths, so it is also important to avoid
hanging cloths on spouts.
Wall Outlet Installation
Choose the location for the wall outlet
and create a 25-30mm hole in the wall.
Ensure your shower accessories have
enough reach from that position.
Finish the wall surface.
Servicing Intervals
To reduce the build up of lime scale and to
ensure this shower works to its maximum
performance we recommend this shower
is serviced every 6-12 months depending
on the hardness of your water.
Maintenance - Cartridge Cleaning
1
2
Remove the
handles.
Gently
IMPORTANT
remove the
Isolate the
concealing
water supply
plate from
before
the wall.
starting!
2.5
mm
4
5
Remove any O-rings and soak all
components in de-scaler and wash off
in clean water. Examine all seals and
Reverse the installation steps,
replace if needed. Use WRAS
ensuring the temperature
approved silicon based grease
stop is aligned correctly.
on all seals.
Operation
Top
Outlet On/
Increased Flow
Increased
Temperature
Bottom
Outlet On/
Increased
Flow
With rear access
Fit the wall outlet,
ensuring the
washers are fitted
either side of
the wall.
Go to Step 6 in the
Installation Steps.
Without rear access
Screw the wall outlet into
Follow Step 6 in the
the 1/2" female connection,
Installation Steps, fitting a 1/2"
using a suitable thread sealant
female connection at the hole in
ensuring the rubber seal is fitted
the wall (not supplied).
to the back of the wall outlet.
3
6
Decrease
1
Temperature
2
3
Follow the Temperature
Adjustment Steps if required.
Troubleshooting
Top
Symptom
Outlet Off/
Partially closed isolation valve.
Decreased
Instantaneous water heater cycles on and off
Flow
as flow rate or pressure is too low.
Head of water is below the
Decreased
minimum distance required.
Temperature
Are the water supply pressures balanced?
No flow or
Bottom
low flow rate
Hot or cold water being drawn off elsewhere
Outlet Off/
causing pressure changes or instantaneous
Decreased
boiler temperature changes.
Flow
Airlock or partial blockage in the supply
Hot/Cold water supply has failed
Maximum
Water
Maximum Water Temperature
Temperature
too Hot/Cold
Installtion conditions outside
Hot water temperature is less than 10°C
Outlet Water
above the required blend temperature
Temperature
too Hot/Cold
Instantaneous water not igniting because the
water flow rate is too low.
Instantaneous water not igniting because the
water pressure is too low.
Only hot/
Inlet water supplies are reversed.
cold water
Unscrew the
from Shower
shrouds.
Valve
Remove the
cartridges
This is normal for a short time after using the
Water
and piston.
dripping
If water continues to drip,
from shower
possibly due to the cartridge
Shower does
not turn on
24
Mains water supply turned off.
mm
Our Guarantee
At Bristan, we want to make things as easy as possible for our customers. That's why we offer
solid guarantees on all our products, effective from the date of purchase, to give you peace of mind.
To start your free guarantee simply scan the QR code and register your product.
Alternatively visit www.bristan.com/register.
For any other queries, please call our Customer Service on 0330 026 6273
Increase
where our expert team of advisors will be able to offer you any help and advice.
Temperature
For full guarantee terms and conditions visit www.bristan.com/service-centre/guarantees.
Bristan Group Ltd.
UK:
Bristan Group, B78 1SG.
EU:
Masco Europe S.à.r.l., 14 Rue Strachen
6933 Mensdorf, Luxembourg.
Cause
If pressures are unbalanced, a pressure reducing valve
should be used for optimum performance.
Do not use other water outlets when using the shower.
Flush through pipework and filters to ensure removal
pipework.
Check the hot and cold feeds. The shower will not
Refer to the Temperature Setting section to set your
needs adjusting.
Flush through pipework and filters to ensure
Filter/pipe blockage
removal of debris and any airlocks.
operating parameters.
Adjust hot water temperature or wait for water to
reheat if a stored water system is used.
Increase water flow rate through the system. Refer to the
Maintenance section to clean/check the cartridge and filters
for any damage. Contact your boiler manufacturer.
Refer to the specification for system requirements.
Increase water pressure through the system.
Check the water inlet connections are the correct way
around: Hot on the left, Cold on the right when viewed from
the front. Rework pipework as necessary.
Flush through pipework and filters to ensure removal of
Filter/pipe blockage
This is caused by residual water tension, the build up of
shower.
Remove cartridge and clean, refer to 'Maintenance' section
Closed isolation valve.
Customer Service: +44330 026 6273
Web:
www.bristan.com
Email:
A Masco Company
Remedy
Open isolation valve.
Increase water flow rate or
pressure through system.
Refer to the specification for the
minimum distance required.
of debris and any airlocks.
work if either fails.
desired maximum temperature.
Refer to the specification for the
minimum distance required.
Contact your boiler manufacturer.
debris and any airlocks.
water in the shower.
before starting any maintenance.
Open isolation valve.
Turn on mains water supply.