Installation Cont.
Bath Spout
1. Terminate sufficient pipework
inside the wall cavity to a 1/2" BSP
female fitting ensuring pipework is
fixed in position and rigid so that it is
unable to move.
2. Screw the spout connecting tube
into the female fitting (using a suit-
able thread sealant) ensuring the
spout connecting tube is fully tight-
ened.
3. Finish the wall surface and tile up
to the spout connecting tube.
4. Push the spout and plate onto the
spout connecting tube and secure in
place by tightening the grub screw
on the
underside of the spout.
5. Turn on both water supplies letting
the water flow for a few minutes.
6. Check all joints and connections
for leaks.