Troubleshooting
Symptom
Flow of water
Inlet water supply pressure too
too high.
high.
Spout runs
Object in the sensing range.
randomly
Reflective surfaces, i.e. High
without a user
Visibility jacket/clothing activate
present.
the sensor.
Sensor light faulty.
Sensor light
Circuit board faulty or has been
not working.
allowed to get wet.
Batteries are exhausted.
Short cycles
Incorrect batteries fitted.
of batteries.
Infrared
sensor
Batteries running low.
flickering.
Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.
Cause
Remedy
Adjust inlet water pressure
accordingly. Refer to the
'Specification' section.
Ensure the sensing range is clear.
Ensure that the product is at least
360mm from reflective surfaces.
Contact Bristan Customer
Services.
Replace batteries.
Replace batteries. Ensure
batteries are 1.5V AA (LR6)
Alkaline batteries (preferably
=>2000mAh) for good battery
life.
Replace batteries. Ensure
batteries are 1.5V AA (LR6)
Alkaline batteries (preferably
=>2000mAh) for good battery
life.