Majestic fireplaces FireStage UV36 Homeowner's Installation And Operating Instructions Manual - Page 9

Browse online or download pdf Homeowner's Installation And Operating Instructions Manual for Indoor Fireplace Majestic fireplaces FireStage UV36. Majestic fireplaces FireStage UV36 12 pages. Vent-free gas firebox
Also for Majestic fireplaces FireStage UV36: Brochure & Specs (6 pages), Homeowner's Installation And Operating Instructions Manual (12 pages), Specifications (2 pages)

Majestic fireplaces FireStage UV36 Homeowner's Installation And Operating Instructions Manual
Soffit Termination
Duct
Termination
40' Max.
Duct Run
Exterior Wall Termination
Exterior Wall
Rain Cap
Duct Termination
Fig. 7 Typical outside air installations.
Cover Plate
Fig. 8 Remove outside air cover plate and discard, retain
screws.
4. At the termination end, install the duct termination.
This should be installed from the outside of the
home. Cut a hole in the desired location approxi-
mately 4¹⁄₂" (114mm) in diameter, caulk around the
hole, and slide the termination through the opening
from outside the home. The termination/rain cap
20007446
Attic
Ceiling
Duct
40' Max. Duct Run
Duct
FP1060
FP1060
AKMST installation
7/6/00 djt
KT143
KT143
AKU cover plate
9/5/00 djt
should be caulked around its perimeter to assure a
tight seal. The rain cap opening should be positioned
downward. (Fig. 10)
The Outside Air Kit is now installed and ready for use.
Fig. 9 Secure the inlet collar assembly.
Caulking
Wall
Fig. 10 Caulk and install duct termination/rain cap in place.
Operating Precautions and Instructions
Operation is automatic. A slight negative pressure inside
the house will open the barometric flapper valve.
Periodically inspect the duct termination for any block-
age. Correct if necessary.