Adey MagnaCleanse User Manual - Page 4

Browse online or download pdf User Manual for Water Filtration Systems Adey MagnaCleanse. Adey MagnaCleanse 12 pages.
Also for Adey MagnaCleanse: User Manual (8 pages)

Adey MagnaCleanse User Manual

Product Overview

MagnaCleanse delivers a fast and effective flushing process for central heating systems.
The process involves ADEY's proven and award-winning MagnaClean technology.
You will need:
MagnaCleanse system contents, including:
MagnaCleanse RapidFlush filter
VibraClean
radiator agitator
®
MagnaCleanse adaptor kit
MagnaCleanse hose-to-valve connector
Hose lengths (x2)
Hose clamps (x6)
Female camlocks (x2)
Tri-clamps (x2)
Drain valve
You will also need (not included with the system):
Flexible hoses with isolators
Pressure reducing valve and gauge
MagnaClean domestic filter
To achieve the best protection for the boiler, it is
important that the system flush is carried out with the
MagnaCleanse hose-to-valve connector attached to
the return pipe of the system.
For maximum effect it is recommended that cleaner is
added for a minimum of 1 hour:
MC3+
- Leave for up to 28 days.
®
MC5+
- Leave for up to 7 days.
®
The following instructions are designed to assist
engineers in the safe and effective operation of the
MagnaCleanse.
These instructions are for open vented heating
systems. If the system is a combination or sealed
system, please refer to the MagnaCleanse
User Guide for Combination
and Sealed systems.