Bristan MT503CP Installation Instructions And User Manual - Page 5
Browse online or download pdf Installation Instructions And User Manual for Control Unit Bristan MT503CP. Bristan MT503CP 12 pages. Temperature stabilised thermostatic mixing valve
Installation
IMPORTANT: Please ensure both supply pipes are flushed before connecting the
mixing valve to prevent plumbing/pipe debris from entering the mixing valve.
Also ensure that the mixing valve is situated in a place where the commissioning,
testing and maintenance of to TMV standards can be undertaken.
Please read the TMV guide supplied with this product for more information.
If you have purchased MT503CP; we advise installing isolation valves as close as its
practical to the mixing valve for ease of maintenance.
Please check component drawings for completeness before starting installation.
1. Plumb the pipes to the desired
location for the mixing valve,
ensuring that they're secure in
position.
2. Connect the valve to the pipework,
We recommend using a high
tightening torque (45-50Nm) on
all compression fittings to secure
the valve.
IMPORTANT: Please ensure both
supply pipes are flushed before
connecting the mixing valve to
prevent plumbing/pipe debris from
entering the mixing valve.
Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.
Remember: Ensure the valve is fitted
with the hot inlet on the left, cold
on the right when viewed from the
front.
3. Connect your chosen outlet to the
mixing valve. Turn on the water
supply and check all joints and
connections for any leaks.
4. Please refer to the TMV guide in
order to test and commission the
mixing valve.
5