Airflow 8QRKDE Installation And Operating Instructions Manual - Page 7
Browse online or download pdf Installation And Operating Instructions Manual for Fan Airflow 8QRKDE. Airflow 8QRKDE 16 pages. External wall insulation vent kit
4.0
CHAPTER 4
POSITIONING/
ASSEMBLY
m
NOTE
Insulation thickness
© Airflow
we reserve the right to make changes without prior notice
-
Installation overview soffit element
Installation requirements soffit element:
1. Wall thickness of uncovered wall: min. 240 mm to max. 480 mm
2. Insulation panel thickness: min. 100 mm
3. Horizontal distance from core drilling hole to soffit (ready-mix plaster): min. 220 mm to max. 500 mm (see Fig. 6)
4. Vertical distance from core drilling hole to window lintel: min. 300 mm
5. Note the installation instructions for shutters and blinds in Figure 4!
6. Can be used for fire protection class B1 (flame resistant)
Uncovered wall+ready mix plaster
min. 280
Soffit channel
100
Wall insulation sleeve
( min. 300 )
20 ± 3
74
Uno hab Ext. Wall Ins. Vent Kit
Fig.4
7
Installation and Operating Instructions
Length of wall installation sleeve
ò
Max.: 500 mm
Min.: 300 mm
The length of the wall installation sleeve
comprises the thickness of the uncovered
wall with internal ready-mix plaster, the height
of the feet (
) of the soffit channel and the
ä
immersion depth (
) in the soffit channel
ù
(see Fig. 4 & 5).
m NOTE: The length of the wall installation
sleeve should be adjusted so that there are
no collisions in the area of the shutter rail.
Immersion depth of the wall installation
ù
sleeve in the soffit element
Length: 20 mm
m NOTE: The wall installation sleeve must
not be cut off flush with the wall on the outside!
Soffit channel feet
ä
Max.: 40 mm
Min.: 0 mm
The soffit channel feet determine how far it
sits from the uncovered wall. The height of
the feet and the height of the soffit channel
of 100 mm corresponds to the min. insulation
thickness. If necessary, the feet can be
underpinned .
Distance from core drilling hole (centre)
ë
to the end of the soffit channel
Max.: 480 mm
Min.: 200 mm
The adjustable length of the channel must
be selected depending on the distance
between the core drilling hole (centre) to the
ready-mix plaster in the window soffit. This
distance minus the height of the shortened
plaster frame (
) provides the length of the
ö
shortenable area
.
ë
Height of the plaster frame
ö
Max.: 35 mm
Min.: 15 mm
The height of the plaster frame bridges the
distance between the soffit channel and
the wall grille. The height must be selected
depending on the thickness of the window
soffit insulation and the ready-mix plaster.
The plaster frame allows for tolerance
compensation.
A minimum height of 20 mm is recommended
for the plaster frame.