Green DS540059 User Manual And Installation Handbook - Page 9

Browse online or download pdf User Manual And Installation Handbook for Air Conditioner Green DS540059. Green DS540059 19 pages. Electric air-conditioning unit green gt790 12.000btu 12v

Green DS540059 User Manual And Installation Handbook
3.
TECHNICAL
SPECIFICATION
MODEL
Nominal tension (V)
Current (A)
Power (W)
Refrigerating capacity (W)
Performance coefficient
Refrigerant
Oil
Refrigerant quantity (g)
Speed (RPM)
Internal dimension
(Evaporator Unit) (mm)
External dimension
(Condenser Unit) (mm)
Power cable specification
Electric Air-Conditioning Unit Green GT790 12.000BTU 24V - DS540059
16
Electric Air-Conditioning Unit Green GT790 12.000BTU 12V - DS630051
DS630051
DS540059
12
24
60-80
15-45
960
950
1000 - 3000
≥ 2,5
R134a
ISO VG 68
600
1000 - 3000
460 X 160 X 320
660 X 490 X 210
3.0m x 8mm
4.
INTERNAL BOARD
ERROR CODE
(EVAPORATOR UNIT)
In case the following codes appear at the
display during air-conditioning usage,
it might indicate expressive failures to/
with the product. For correction, follow
as below:
- Reduce air-conditioning speed and turn
it off, after approximately 10 minutes,
restart the air-conditioning system. In
case the code persists, turn off the system
and contact
specialized assistance. (If
the code disappears, you can continue
using it).
Error Codes:
-
E01
Tension/battery is low;
-
E02
A probable bad connection of the
Blower Motor – check cables, connec-
tors or need of replacing the Blower
Motor;
H22
-
Inlet sensor failure, which indicates
the mode might alter after returning to
normal function;
ADVICE:
IF THE ALERT CODE THAT APPEARS AT THE COMPRESSOR´S FAILURE
INDICATOR DOES NOT CORRRESPOND TO THE CODES AS DESCRIBED AT THE TABLE
ABOVE, THE COMPRESSOR´S CONTROLLING PANEL MUST BE REPLACED
Electric Air-Conditioning Unit Green GT790 12.000BTU 24V - DS540059
Electric Air-Conditioning Unit Green GT790 12.000BTU 12V - DS630051
H23
-
Outlet sensor failure, which indi-
cates the mode might alter after return-
ing to normal function;
E04
-
Temperature sensor of the pipe
(Air-Outlet);
E05
-
Compressor is overheating and
as soon as the Compressor´s temper-
ature goes down; it returns to normal
function;
E06
-
Check if the circuit, coming from
the Compressor in direction to the Con-
denser Fan, is open;
E07
-
Check for a possible short circuit
between the Compressor and Condens-
er Fan;
E09
-
Defect at the command board of
the Condenser Fan – Board must be
replaced;
E10
-
Replace the Condenser Fan;
E11
-
Check a possible damage caused to
the cables connecting the Compressor
to the Condenser Fan.
17