INSTALLATION STEPS
STEP 1.
Unpackage your freestanding bath. Check for damage
and ensure your bath does not come in contact with any
rough surfaces which may scratch your bath. Place your
freestanding bath on cardboard or carpet during installation.
Check the contents of the carton include the following:
1. Complete spa bath with the pipework and touch pad
installed
2. Pump carton wrapped in foam
3. An installation kit consisting of:
a. Control cable for pump
b. 2 x 90'elbows
c. 2 x couplings for install and serviceability
d. 1 x cover plate
4. A pop-down overflow kit
5. A pop-down waste with connector
If any of these items are missing, please immediately
contact your retailer.
STEP 2.
Place the freestanding bath in the correct position for
installation.
Adjust the leveling feet until the bath base is 3-5mm above
the finished floor. If measuring from the unfinished floor take
into account the floor finishing thickness (such as tiles) into
account. Turn the feet bolts and level accordingly.
Ensure there is 3-5mm of space between the bottom of
the bath shell and the floor. Installing directly on the floor
will place pressure on the outside wall of the bath, and will
potentially crack the bath.
Ensure the bath is level so all water can drain to the waste outlet.
2 | DECINA INSTALLATION MANUAL
STEP 3
Carefully tilt the bath (or support in raised position) and install
the overflow and waste as per manufacturers installation as
provided in the cartons.
STEP 4 PUMP MOUNTING
With the bath level set (and levelled) confirm the centre points
for the 2 x 40mm couplings on the back of the spa. These are
nominally 210mm and 295mm, but the measurements must
be confirmed prior to proceeding.
Once the height has been confirmed,
measure centrepoints on the
corresponding wall (again measuring
from the same floor level) and drill 2
x 75mm (minimum) holes through the
wall to the exterior, or the location
where the pump will be located.
Determine the distance from the back of the bath to the other
side of the wall, and cut 2* pieces of 40mm pipe (not supplied)
to be able to fit from inside the couplings on the back of the
bath, through the wall, and have 100mm on the other side of
the wall (this will be trimmed once installed through the wall)
Glue these pipes into the couplings on the back of the bath.
Connect the controls lead to the touch pad on the pump,
and feed the end with the rubber cap on it through the holes
created above. Once this has been fed through, push the pipes
through the holes, and the bath against the wall.
3-5mm gap
between the bottom