KitchenAid Architect Series II KGCK366V Install Manual

Browse online or download pdf Install Manual for Cooktop KitchenAid Architect Series II KGCK366V. KitchenAid Architect Series II KGCK366V 1 pages. Gas built-in cooktop
Also for KitchenAid Architect Series II KGCK366V: Dimensions (1 pages)

KitchenAid Architect Series II KGCK366V Install Manual
PRODUCT MODEL NUMBERS
KGCK306V
KGCK366V
Gas Supply: This cooktop is factory set for use
with Natural gas. Cooktop can be converted to LP
gas. Provide a gas supply line of
pipe to the cooktop location. A smaller size pipe on
longer runs may result in insufficient gas supply.
Pipe-joint compounds that resist the action of LP
gas must be used. Do not use TEFLON
LP gas, piping or tubing size can be
Usually, LP gas suppliers determine the size and
materials used in the system.
Electrical: A 120 volt, 60 Hz., AC only, 15-amp
fused, electrical circuit is required. A time-delay
fuse or circuit breaker is also recommended. It is
recommended that a separate circuit serving only
this cooktop be provided.
CABINET OPENING DIMENSIONS
C
K
M
J
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
®
Gas Built-in Cooktop
OVERALL DIMENSIONS
" (1.9 cm) rigid
®
tape. With
" minimum.
A
D
B
F
G
E
H
L
I
A
A. 31
" (79.8 cm) on 30" (76.2 cm) models,
37
" (95.4 cm) on 36" (91.4 cm) models
B. 21 " (53.4 cm)
C. 2 " (7.3 cm)
"
A. 30
(76.2 cm) on 30
B. Combustible area above countertop (shown by dashed box
above)
"
C. 30
(76.2 cm) minimum clearance between top of cooktop
platform and bottom of unprotected wood or metal cabinet
"
(24
[61 cm] minimum clearance if bottom of wood or metal
cabinet is protected by not less than
retardant millboard covered with not less than No. 28
MSG sheet steel, 0.015
"
0.024
[0.06 cm] aluminum or 0.020
"
D. 13
(33 cm) recommended upper cabinet depth
"
E. 2
(5.4 cm)
"
F. 19
(48.3 cm)
G. 18" (45.7 cm) minimum clearance from upper cabinet to
countertop within minimum horizontal clearances to cooktop
H. Grounded outlet - Locate within 24" (61 cm) of right rear
corner of cutout
I. 29" (73.7 cm) on 30" models; 35¼" (89.5 cm) on 36" models
J
J. 8 " (21.3 cm) minimum distance to nearest left and right side
combustible surface
K. 2 " (7.3 cm) minimum distance to rear combustible surface
L. Gas line opening - Wall: anywhere 5" (12.7 cm) below
underside of countertop. Cabinet floor: Anywhere within
6" (15.2 cm) of rear wall is recommended
M. 24" (61 cm) minimum countertop depth is required
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
B
C
"
"
"
models; 36
(91.4 cm) on 36
"
[0.6 cm] flame
"
[0.04 cm] stainless steel, or
"
[0.05 cm] copper)
models
Ref. W10131955
3-25-08