Major tech MT775 Instruction Manual - Page 7

Browse online or download pdf Instruction Manual for Measuring Instruments Major tech MT775. Major tech MT775 20 pages. Ac/dc trms clamp meter
Also for Major tech MT775: Instruction Manual (16 pages)

Major tech MT775 Instruction Manual
5. SPECIFICATIONS
AC Current
Range
Measuring Range Resolution
40A
0 ~ 40.00A
400A
0 ~ 400.0A
1000A
0 ~ 1000A
DC Voltage
Range
Measuring Range Resolution
400mV
0 ~ 400.0mV
4V
0 ~ 4.000V
40V
0 ~ 40.00V
400V
0 ~ 400.0V
600V
0 ~ 600V
AC Voltage
Range
Measuring Range Resolution
400mV
0 ~ 400.0mV
4V
0 ~ 4.000V
40V
0 ~ 40.00V
400V
0 ~ 400.0V
600V
0 ~ 600V
Note: No Autoranging on 400mV AC Range
Resistance
Range
Measuring Range Resolution
400Ω
0 ~ 400.0Ω
4kΩ
0 ~ 4.000kΩ
40kΩ
0 ~ 40.00kΩ
400kΩ
0 ~ 400.0kΩ
4MΩ
0 ~ 4.000MΩ
40MΩ
0 ~ 40.00MΩ
Capacitance
Range
Measuring Range Resolution
4nF
0 ~ 4.000nF
40nF
0 ~ 40.00nF
400nF
0 ~ 400.0nF
4µF
0 ~ 4.000µF
40µF
0 ~ 40.00µF
400µF
0 ~ 400.0µF
4mF
0 ~ 4.000mF
40mF
0 ~ 40.00mF
Frequency
Range
Measuring Range Resolution
4kHz
0 ~ 4.000kHz
Temperature
Range
Measuring Range Resolution
-40ºC ~ 1000ºC
ºC
-40.0ºF ~ 1832ºF
ºF
6
Accuracy (% of Reading)
0.01 A
± (2.8% + 10 digits)
0.1 A
± (2.8% + 8 digits)
1 A
± (3.0% + 8 digits)
Accuracy (% of Reading)
± (0.8% + 2 digits)
0.1 mV
0.001 V
± (1.5% + 2 digits)
0.01 V
0.1 V
± (2.0% + 2 digits)
1 V
Accuracy (% of Reading)
± (1.0% + 10 digits)
0.1 mV
0.001 V
± (1.5% + 8 digits)
0.01 V
0.1 V
± (2.0% + 8 digits)
1 V
Accuracy (% of Reading)
± (1.0% + 4 digits)
0.1 Ω
± (1.5% + 2 digits)
10 Ω
100 Ω
± (2.5% + 5 digits)
1 kΩ
± (3.5% + 10 digits)
10 kΩ
Accuracy (% of Reading)
± (5.0% + 30 digits)
0.001 nF
± (5.0% + 20 digits)
0.01 nF
0.1 nF
± (3.0% + 5 digits)
0.001 µF
0.01 µF
± (4.0% + 10 digits)
0.1 µF
± (4.5% + 10 digits)
0.001mF
± (5.0% + 10 digits)
0.01mF
Accuracy (% of Reading)
± (1.5% + 2 digits)
0.001 kHz
Sensitivity: 5Vrms min
Accuracy (% of Reading)
± (2.5% + 3ºC)
1 ºC
1 ºF
± (2.5% + 5ºF)