6.2. AC Voltage Measurement

WARNING: Risk of Electrocution. The probe tips may not be long enough
to contact the live parts inside some 240V outlets for appliances because
the contacts are recessed deep in the outlets. As a result, the reading may
show 0 volts when the outlet actually has voltage on it. Make sure the
probe tips are touching the metal contacts inside the outlet before
assuming that no voltage is present.
CAUTION: Do not measure AC voltages if a motor on the circuit is being
switched ON or OFF. Large voltage surges may occur that can damage the
meter.
1. Set the function switch to the highest VAC Position.
2. Insert the black test lead banana plug into the negative COM Input Jack;
Insert the red test lead banana plug into the Positive Input Jack.
3. Touch the black test probe tip to the negative side of the circuit; Touch
the red test probe tip to the positive side of the circuit.
4. Read the voltage in the display.
5. Reset the function switch to successively lower VAC Position to obtain a
higher resolution reading, the display will indicate the proper decimal
point and value.
12