3. MEASURING INSTRUCTIONS
Remove the cap to expose the needle electrodes OR Connect the heavy
duty moisture probe socket on the right hand side of this instrument and
switch-on by pressing " ". Select the appropriate wood calibration scale
(A, B, C, E, F, G, H or J) by referring to the enclosed wood calibration
table and pressing " ". Push into the wood and observe the reading.
4. USING THIS INSTRUMENT WITHOUT THE TEMPERATURE
PROBE
The instrument is calibrated for wood at 20°C (68°F). In general, timber
that is hotter than 20°C will give higher readings and timber colder than
20°C will give lower readings. An approximate manual correction of 0.5%
moisture content per 5°C may be subtracted from timber that is above
20°C. For timber that is below 20°C, a manual correction of 0.5%
moisture content per 5°C may be added to the measured value.
5. AUTOMATICALLY TEMPERATURE CORRECTED (ATC)
Switch the instrument on and select the appropriate wood calibration
scale as detailed in sections 1. Using a hammer and nail of nominal 3 mm
diameter, make a hole in the wood to be tested. Remove the nail and
push the Temperature Probe into the hole until the tip is at the required
depth. Connect the Temperature Probe into the instrument via the "Temp"
socket. Then using this instrument to measure timber can obtain the
automatically temperature corrected (ATC) moisture value. If you need to
read current temperature of timber press "T" button, then LCD will display
the temperature. Press "T" button the LCD will display either °C or °F
temperature. Pressing "
(Temperature Range: -35°C ~ 80°C).
6. SET-UP AUTOMATICALLY SWITCH-OFF TIME
Combinatorial using " " + " " button can change the default
automatically switch-off time. Depress the " " button don't release and
press the " " button will automatically change the switch-off time
(disable automatically switch-off or set from 1 to 9 minutes) by changing
the code as detailed in the following table.
Code
0
Disables automatic switch-off
1
Selects automatic switch-off at 1 minute
2
Selects automatic switch-off at 2 minutes
3
Selects automatic switch-off at 3 minutes
...... ......And so on to......
9
Selects automatic switch-off at 9 minutes
" button the LCD display moisture value again.