Major tech MTD70T Instruction Manual - Page 6

Browse online or download pdf Instruction Manual for Measuring Instruments Major tech MTD70T. Major tech MTD70T 12 pages. 600a ac true rms digital clamp meter

Major tech MTD70T Instruction Manual

3. General Specifications

Basic Functions
Clamp jaw opening
Display
Low Battery indication
Over-range indication
Measurement rate
Input Impedance
AC response
ACV Bandwidth
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Operating Altitude
Battery
Battery life
Auto power OFF
Dimensions
Weight
Safety

4. Specifications

4.1. AC True RMS Current

Range
2.000A
20.00A
200.0A
600A
Over range protection: Maximum input 600A
Accuracy specified from 5% to 100% of the measuring range
Frequency Response: 50Hz to 60Hz True RMS
6
Range
28mm approx.
2000 Count (2-1/2 digits backlit LCD)
'OL' display
3 readings per second, nominal
10M (VDC and VAC)
Average Reading (AAC and VAC)
2KHZ
5°C to 40°C (41°F to 104°F)
-20°C to 60°C (-4°F to 140°F)
Max 80% up to 31°C (87°F) Decreasing
linearly to 50% at 40°C (104°F)
<80%
2000meters (7000ft.) maximum.
2 x 1.5V AAA Battery
Approx. 30h (backlight ON), Approx.
100h (backlight OFF)
After approx. 15 minutes
185 x 65 x 37mm
180g
For indoor use and in the requirement
For double insulation IEC1010-1(2001):
EN61010-2-030, EN61010-2-032,
EN61010-2-033 Over voltage Category
III 600V, Pollution Degree 2.
Resolution
1mA
10mA
100mA
1A
is displayed
Accuracy (% of reading + digits)
±3.0% of rdg±5 digits
±2.0% of rdg±5 digits