Major tech MTD73A Instruction Manual - Page 17
Browse online or download pdf Instruction Manual for Measuring Instruments Major tech MTD73A. Major tech MTD73A 20 pages. 800a ac true rms digital clamp meter
REL Mode
This sets the relative point to measure against the next reading.
Press the REL key to enter the Relative Measurement Mode, this
function resets the display to zero.
Automatic Power OFF
In order to conserve battery life, the meter will automatically
turn off after approximately 15 minutes. To turn the meter on
again, turn the rotary function switch to the OFF position and
then to the desired function range.
To cancel the auto power off function, press SELECT button and
turn on the power with the rotary switch at the same time.
Maintenance
WARNING: To avoid electrical shock, disconnect the meter
from any circuit, remove the test leads from the input
terminals, and turn OFF the meter before opening the case.
Do not operate the meter with an open case.
Cleaning and Storage
Periodically wipe the case with a damp cloth and mild detergent;
do not use abrasives or solvents. If the meter is not to be used
for 60 days or more, remove the battery and store it separately.