7. Electrical setup
1.
Always check that the circuit breaker in the
electrical panel is in the OFF position, and that
all high voltage circuits (more than 42.4V) are
completely isolated from the mains supply
before doing any work.
2.
Ensure that all low voltage systems (less than 42.4V) are
suitably protected from damage, by disconnecting all
sources of power such as chargers and batteries before
doing any work.
3.
All electrical work must be carried out according to the
requirements of all applicable local electrical codes. (It is
recommended that a licensed electrical contractor perform
such work).
Connect all wiring
Connect the controller to the required input and output devices as per
the wiring diagram on the right hand side.
8. Description of terminal functions
Light/Light
Pillar light connection.
(A normally-open potential-free input)
Safe Common
Used for switching the power supply to the safety
beams, if automatic beam testing is required
Aux 12V Out
Auxiliary power connection.
Provides +12V DC supply for auxiliary equipment
such as a radio receiver, photo cells, etc. It is
electronically limited to 300mA
Safety Close
Closing beam safety input.
(A normally-closed potential-free input)
Safety Open
Opening beam safety input.
(A normally-closed potential-free input)
Lck/Stp
Holiday Lockout or emergency stop input.
(A normally-closed potential-free input)
Trg
Trigger input.
(A normally-open potential-free input)
FRX
Free-exit input.
(A normally-open potential-free input)
Aux
Activates the pillar light relay.
(A normally-open potential-free input)
Ped
Pedestrian opening input.
(A normally-open potential-free input)
Com
Common termination point.
All trigger signals, etc. have their return path to one
of the Com terminals
Status
External gate status indicator.
(A low current output signal). An output terminal
which provides a low current drive (approx. 4,5V
DC, 20mA) to a LED which can be used to indicate
the gate status remotely)
Aux IO
The Aux IO terminal provides an open collector
output which can be used for alarm or auto function
purposes
Motor
Motor output
D5-Evo - connects to the black motor wire
D10/D10 Turbo - connects to the blue or black
motor wire
Motor
Motor output
D5-Evo - connects to the blue motor wire
D10/D10 Turbo - connects to there orange or red
motor wire
12V/24 +
Positive battery connection.
Battery terminal normally indicated as + or
red (right hand battery)
12V/24 -
Negative battery connection.
Battery terminal normally indicated as - or
black (left hand battery)
12V/24V this will either be 12V or 24V depending on the motor
voltage of the operator
A switch that remains in a connected or
Latched
disconnected state similar to a standard light switch
A switch that momentarily makes contact, and may
Non-Latched
be spring loaded similar to a push button door step
9. Installation handover
Once the installation has been successfully completed and tested, it is
important for the installer to explain the operation and safety
requirements of the system.
i5 Infrared safety beams
optional, but
(opening and closing)
recommended
Connection type: Normally-closed
Rx
IRB Receiver
Tx
IRB Tx
Holiday lockout
optional
keyswitch/keypad
Connection type: Normally-open
Latched
POLOphone Intercom
optional
push button
Connection type: Normally-open
Non-latched
Pedestrian
Keyswitch/Keypad
optional
Connection type: Normally-open
Pillar light
optional
pushbutton
Connection type: Normally-open
POLOphone
optional
handset status LED
Connection type: Normally-open
12V+
Neg
COM
NC
NO
There is an onboard CENTURION receiver.
Switch off the receiver if not being used
Hold-down
optional, but
Lightning rod
base plate bolt
recommended
OR
Earth spike
(>1m copper
rod hammered
into the ground)
Loop and Loop
optional
Detector
Loop Detector
NO
NC
COM
Neg
12V+
Pillar Light/
optional
Courtesy Light
L N E
Optional 40kA
surge arrestor
E
N
L
L
N
E
Charger
Weatherproof
isolator enclosure
within two metres
of motor
E
N
L
110 - 220V
Mains in
Battery
Only one 12V battery is used for the D5-Evo