MAJORCHARGE MajorCharge24/5 Owner's Manual - Page 2
Browse online or download pdf Owner's Manual for Battery Charger MAJORCHARGE MajorCharge24/5. MAJORCHARGE MajorCharge24/5 8 pages. Gel, pro, hd series 6/8/12/16/24/36/48 volt
12/24/36/48 Volt
DIMENSIONS
•
12"L x 7"W x 7"H
Model
MajorCharge12/25
117VAC, 60Hz, 480VA 12VDC, 25A
MajorCharge24/25
117VAC, 60Hz, 850VA 24VDC, 25A
MajorCharge36/20
117VAC, 60Hz, 1120VA 36VDC, 20A
MajorCharge48/20
117VAC, 60Hz, 1400VA 48VDC, 20A
Suitable for use with all types of lead-acid batteries,
including the new types of maintenance-free and gelled
electrolyte batteries.
OPTIONAL EXPORT AC INPUT RATINGS
•
100 V – 50 Hz AC Input (Japan)
•
115/230 V – 50 Hz AC Input (Europe) (CE)
•
Full Wave Phase Controlled Rectification
CONTROL
•
Voltage limited to 2.42 V/Cell (Normal Mode)
•
2.33 V/Cell (Gel-Cell Mode)
•
2.62 V/Cell (Liquid Electrolyte Mode)
•
Current limited to AMP rating MEAN DC
•
Automatic timer starts when first stage voltage
limit reached. Proportional CV stage timer –t/2+1
hour.
•
Constant voltage 2.3 V/Cell after timeout, with
temperature compensation.
PROTECTION
•
Electronic reverse polarity.
•
Short circuit shutdown and current limit.
•
Combined circuit breaker and power switch on
front panel.
BATTERY TYPE & RATING
•
HD Chargers are for use with Lead Acid Batteries
of minimum capacity 50 AH, Gel Cell, Absorbed
Electrolyte or Liquid Electrolyte types by using the
BTS (Battery Type Switch)
MajorPower.Com
Input
Output
12/24 Volt
DIMENSIONS
•
6"L x 6.5"W x 5.25"H
Model
MajorCharge12/5
117VAC, 60Hz, 110VA
MajorCharge12/10
117VAC, 60Hz, 220VA 12VDC, 10A
MajorCharge24/5
117VAC, 60Hz, 200VA
MajorCharge24/8
117VAC, 60Hz, 320VA
Suitable for use with all types of lead-acid batteries,
including the new types of maintenance-free and gelled
electrolyte batteries.
OPTIONAL EXPORT AC INPUT RATINGS
•
100 V – 50 Hz AC Input (Japan)
•
115/230 V – 50 Hz AC Input (Europe) (CE)
•
Full Wave Phase Controlled Rectification
CONTROL
•
Voltage limited to 2.42 V/Cell (Normal Mode)
•
2.33 V/Cell (Gel-Cell Mode)
•
2.62 V/Cell (Liquid Electrolyte Mode)
•
Current limited to AMP rating MEAN DC
•
Automatic timer starts when first stage voltage
limit reached. Proportional CV stage timer –t/2+1
hour.
•
Constant voltage 2.3 V/Cell after timeout, with
temperature compensation.
PROTECTION
•
Electronic reverse polarity.
•
Short circuit shutdown and current limit.
•
AC input fuse in AC input connector.
BATTERY TYPE & RATING
•
PRO Chargers are for use with Lead Acid
Batteries, Gel Cell, Absorbed Electrolyte or Liquid
Electrolyte types by using the BTS (Battery Type
Switch)
Input
Output
12VDC, 5A
24VDC, 5A
24VDC, 8A
http://www.majorpower.com