Green Cubes BDI
The BDI will flash the red light and beep if it needs attention. The
following conditions will trigger the alarm:
Overvoltage
Undervoltage
Over Temperature
Under Temperature
Low State of Charge
The truck operator should stay aware of the battery BDI while in
operation. When the battery gets low (<10%) the BDI will flash and
beep, signaling the battery must be charged. Once the battery is
empty it will cut power to the truck.
Charging Instructions
Batteries without internal chargers are charged either through
their main power connector (Euro or SB), a separate charge port,
or a charge port on the external of the truck. Make sure to use the
appropriate charge port when charging the battery.
Some of the smaller batteries have internal chargers. To charge
these batteries simply use the extension cord provided, and plug
the battery into a standard 110-120VAC outlet.
Use ONLY an approved and properly configured charger to charge
your SAFEFlex lithium-ion battery. Use of an unapproved or
incorrectly configured external charger may damage your battery
and void the warranty. The battery is designed for fast opportunity
charging and charges to specific voltage levels that may not be
programmed into your charger if it has not been approved or
properly configured.
ABOUT GREEN CUBES TECHNOLOGY
Green Cubes Technology harnesses over 30 years of industry experience to ensure we design, develop and deliver solutions for the
most challenging energy needs. We offer battery technology innovation, application design and performance management to drive
productivity, scalability and sustainability.
For more information, email [email protected]
or visit greencubestech.com
Specifications subject to change without notice. Copyright 2020 © Green Cubes Technology
Opportunity Charging
The battery is designed for opportunity charging, and plugging it in
whenever not in use (breaks, lunch, and after hours) will lengthen
the runtime and lifetime of the battery. It is strongly recommend
the battery be plugged in for charging whenever it is not in use.
Operating Temperatures
Standard operational temperatures for the battery are:
Discharge: -4°F - 131°F
Charge: 32°F - 113°F
The battery may have additional options such as internal heaters, if
you wish to operate outside these temperatures.
Storage Temperatures
Storage (<1 month): -4°F - 113°F
Storage (>1 month): 41°F - 68°F
In addition, make sure to turn the battery off while in storage or
while equipment is waiting for deployment. Refer to our extended
storage instructions when planning to store the battery longer than
1 month.
Troubleshooting
If there is an error code on the BDI, follow the appropriate
instructions.
Over Temp: Allow the battery to cool.
Under Temp: Allow the battery to warm.
Over Voltage: Allow the BMS to bleed down the excessively
high voltage.
Under Voltage: Charge the battery.
If the battery has cut power and there is no error code (as detailed
in the Battery Discharge Indicator section) turn the battery off for
30 seconds, then turn it back on.
If this does not fix the issue, contact your dealer or Green Cubes
Technology Service directly at: (765) 831-8009