CENTURION SYSTEMS G-ULTRA Quick Manual
Browse online or download pdf Quick Manual for Measuring Instruments CENTURION SYSTEMS G-ULTRA. CENTURION SYSTEMS G-ULTRA 2 pages.
1. What is G-ULTRA?
Built upon the bedrock of convenience established by the original
G-SWITCH-22 GSM module, the G-ULTRA is a complete evolution of
that device imbued with intelligence and packaged for use in a modern
environment. The combination of a smart graphic user interface and a plethora
of advanced features means that the G-ULTRA goes well beyond the scope
of mere access automation and takes remote monitoring and control to an
entirely new level.
2. Important Safety Instructions
1. Do not install this product near DOSS sensor inside gate motor housing or
2. Do not install this product near any sensitive electrical components.
3. All installation, repair, and service work to this product must be done by a
4. Do not in any way modify the components of the system.
5. Do not install the equipment in an explosive atmosphere: the presence of
6. Do not leave packing materials (plastic, polystyrene, etc.) within reach of
7. Dispose of all waste products like packing materials, according to local
8. Centurion Systems (Pty) Ltd does not accept any liability caused by
9. This product was designed and built strictly for the use indicated in
10. Anything not expressly specified in these instructions is not permitted.
3. Glossary of Terms
Sticky Latches: The module's outputs can be configured to 'remember' their
state between power cycles. For instance, if Output 2 was active, i.e. the relay
in an energised state, and the power is removed, when power is reapplied
Output 2 will return to the activated state. This functionality is referred to as
a 'sticky latch' and can be enabled or disabled. Sticky latched don't apply to
pulsed outputs and are enabled by default.
Filter Time: Filter Time determines how long an input event (rising or falling
edge) must be present before it is recognised, i.e. an SMS or email is sent, or
a missed call is initiated. The time is set in increments of one second and the
default is 0.
Blanking Time: Blanking Time determines how long the unit will wait between
events before it will recognise the next event.
GSM DEVICES
Any Number Mode: When enabled, this useful feature allows any number
to activate the module's outputs, irrespective of whether they are learned into
memory. A typical application would be an event such as a wedding where
G-ULTRA
many guests need to be given temporary access. Instead of manually learning
in a 100 guests and then having to delete them again after the occasion,
QUICK GUIDE
the administrator can simply enable Any Number Mode and disable it again
afterward.
DTMF: Dual Tone Multi-Frequency signaling. This is used for
telecommunication signaling over analogue telephone lines in the voice-
frequency band between telephone handsets and other communication devices
and the switching centre. This allows the user to press a number on his or her
mobile handset to switch any of the outputs on the G-ULTRA.
Channel: An electrical gateway implemented as a physical terminal on the
G-ULTRA that provides the external interface to Input or Output signals
4. Technical Specifications
Supply Voltage Range
Maximum Current Draw
Input/output Current Rating
Relay Contact Current Rating
Input Sense Voltage Range
SIM Card
Number of Configurable
Input/output Channels
Number of Relays
Memory Capacity
Centurion Systems (Pty) Ltd
www.CentSys.com
near the remote receiver.
suitably qualified person.
flammable gas or fumes is a serious danger to safety.
children as such materials are potential sources of danger.
regulations.
improper use of the product, or for use other than that for which the
automated system was intended.
this documentation. Any other use, not expressly indicated here, could
compromise the service life/operation of the product and/or be a source of
danger.
This icon indicates tips and other information that could be useful
during the installation.
This icon denotes variations and other aspects that should be
considered during installation.
11-24V DC
300mA @ 12V DC
50mA (Open Collector)
1A, 30V AC/DC (Resistive)
0-24V DC (0-1.6V Low-input State,
5V-24V High-input State)
Micro-format, Activated SIM
Card Supplied (South Africa only)
1, 2
4
2
• 5000 Event logs
• 20 Access Profiles
• 1 Custom Welcome SMS Message for
New Access Numbers
• 20 Custom Output Activation SMS
Messages (From User to Device)
• 30 Custom Input Notification SMS/Email
Messages (From Device to User)
• 100 Visitor Time-barring Windows
(Windows are the periods between two
dates)
• 30 Generic Time-barring Windows
(Windows are weekly recurring)
• 10 Output Activation Schedules
(Schedules are weekly recurring)
Memory Capacity
• 3 Daylight Saving Periods
(continued)
• 4 Input to Output Mapping
Configurations
Model Options
GSM 2G:
850/900/1800/1900MHz (EDGE)
GSM 3G:
900/2100MHz (EDGE)
TABLE 1
900/2100MHz (UMTS)
GSM 3G PENTA:
800/850/900/1900/2100MHz (UMTS)
1. May not be used in devices other than G-ULTRA (South Africa Only).
2. Remains the property of Centurion Systems (Pty) Ltd. (South Africa Only).
5. Product Identification
1
7
6
2
3
5
4
FIGURE 1
5. Terminal Blocks
1. Fascia
2. External Antenna Cover
6. Navigation panel
3. Main G-ULTRA Unit
7. LCD Screen
4. Mounting Plate
6. Product Dimensions
114.4mm
33mm
FIGURE 2
7. Functional Feature Highlights
Access Number Profiles
The access number configuration profiles eliminates the hassle of configuring
input and output permissions and notifications every time that a new number
is added.
Intelligent Gate Status Monitoring
With seamless integration with CENTURION gate motors, the G-ULTRA will let
the user know when his or her gate has been left open, or is in any other state
specified by the user through intelligent monitoring of the gate motor's status
output. Adjustable Filter settings mean that the user can specify under which
conditions they are notified about a particular gate status, for example if the
gate has remained open for longer than 20 seconds.
Supplied with activated SIM card (South Africa only)
All G-ULTRA units are supplied with an activated Vodacom SIM card (South
Africa only). Airtime can be purchased via G-WEB (South Africa only).
Monitoring and alerting
The device can be configured to monitor up to four separate electrical devices,
such as a home alarm or even a water reservoir. It could send the user an
SMS, give a missed call or even send an email, letting the user know if the
house alarm is on or off or a reservoir is full or empty. When configured as
inputs, the unit's four individually-configurable channels can be configured
to react to Rising Edges, Falling Edges, or both, which makes it ideal for
monitoring variable levels such as mains power. A single input can be used, for
example, to send a notification to users when mains power has failed, and the
same input can notify users once it comes back on, freeing up the other inputs
to take care of monitoring duties for other devices.
Control
In addition to the four configurable channels, two extra relays are provided
which can be used to remotely control electrical devices and appliances
such as gate motors, alarms, geysers and lights, to name but a few possible
applications. Outputs can be activated via missed, SMS text message or by
pressing a number on his or her phone's touchpad.
Timed access control
(Weekly and Visitor) Set arrival and departure dates and times; guests will
only be able to activate the device's outputs between these limits, affording
the user maximum security and affording guests maximum convenience. As a
special value-add developed specifically with B & B owners in mind, customised
arrival and departure messages with welcoming messages, access instructions,
etc., can be sent automatically to guests and visitors.
Alternatively set weekly recurring time-periods (for example 8am to 5pm,
Monday to Friday) during which users will have access to the system.
Outside of the configured time-periods, access will be denied.
Add the ability to map inputs to outputs, customise the input and output
notification messages and use the G-ULTRA in advanced applications.
One has a powerful and convenient GSM-based monitoring and control
solution. Up to 20 separate text messages with up to five scheduled outputs
can be configured.
Time-barring windows can be configured to block notifications, activations or
specific access numbers.
Quick device associations
Devices can be associated to a G-WEB profile in a matter of seconds by simply
scanning a QR code with one's smartphone and a third-party universal QR
scanner application.
Easy access to diagnostics
This smart device provides intelligent feedback via a graphic user interface
displaying status, system information and diagnostic messages for the
complete ULTRA experience.
Smart hardware
An internal GSM antenna ensures healthier, more reliable network signal
strength without the frustration of trying to find the optimal location to mount
the unit. If one needs to fit the G-ULTRA in a metal enclosure, simply attach an
external antenna to the onboard connector.
8. Device Layout and Wire Connections
Optional: External Antenna
NOTE:
The Internal Antenna is
SIM Card
selected by default.
Scroll Left
Scroll Right
Enter /
Home
GND
IO1
IO2
IO3
IO4
NO
COM
NC
NO
COM
NC
+ VDC -
GND
Ground
IO1
Input / Output 1 (Default: Output)
IO2
Input / Output 2 (Default: Output)
IO3
Input / Output 3 (Default: Output)
IO4
Input / Output 4 / Gate Status Input (Default: Output)
NO
Relay 1 Normally-open
COM
Relay 1 Common
NC
Relay 1 Normally-closed
NO
Relay 2 Normally-open
COM
Relay 2 Common
NC
Relay 2 Normally-closed
+
Positive of Power Supply 12-24VDC
-
Negative of Power Supply
TABLE 2
9. LCD Interface
Table 3 below lists the information shown on the different screens found on the
LCD interface. The left and right scroll buttons are used to toggle between the
different screens.
Home Screen
Network Name or Phone Number Applicable to
Incoming / Outgoing SMS or Call.
Network Signal Strength
Connected to Internet
Connected to G-WEB
Device has Error Condition
Home Screen (Continued)
Incoming SMS
Outgoing SMS
Incoming Phone Call Events
Outgoing Phone Call Events
IO Status Screen
Input: Deactivated
("E" = Input event reached)
Input: Activated (pulled to ground)
("E" = Input event reached)
Output: Off
Output: On (pulling to ground)
Output Status Screen
Relay X is Switched OFF and the
Normally-Closed and Common
Contacts are connected.
Relay X is Switched ON and the
Normally-Open and Common
Contacts are connected.
X= 1 or 2
Voltage/Firmware/Date & Time Screen
•
Supply Voltage
•
Time
•
Firmware Version
•
Date
Phone Number Screen
Device SIM Phone Number.
Airtime Balance Screen
Press Enter to Refresh Airtime
Balance from Network Provider.
GSM Antenna Selected Screen
Internal GSM Antenna Selected
(default).
External GSM Antenna Selected
(connect own Antenna to SMA
connector).
Press Enter to change between
Internal and External Antennas.
Gate Status Screen
Gate Closed
Gate Opening
Gate Open
Gate Status Warning
SIM Screen
SIM pin OK
SIM pin Wrong
SIM Error
IMEI Screen
Displays the devices IMEI number
TABLE 3
10. Configurations
10.1. Removing the Mounting Plate and Fascia
To access the terminal blocks of the G-ULTRA, the back plate and fascia
needs to be removed. Follow the instructions below to do this.
10.1.1. Removing the Mounting Plate
Gently pull the two clips at the back, backward to release the main G-ULTRA
unit, and lift the unit out of the mounting plate.
Main G-ULTRA Unit
Mounting Plate
Clips
FIGURE 3