DECODE EMU Series User Manual - Page 10
Browse online or download pdf User Manual for Measuring Instruments DECODE EMU Series. DECODE EMU Series 15 pages. Electricity measurement units
EMU - User manual v1.2
5.1.2
Function 06 - Preset Single Register
The query consists of 8 bytes. This function may be used only in SETUP mode for registers
from 40008 to 40017.
Byte
Field name
1
Device address
2
Function
3
Register address Hi
4
Register address Low
5
Register number Hi
6
Register number Low
7
CRC error check Lo
8
CRC error check Hi
The response consists of 8 bytes:
Byte
Field name
1
Device address
2
Function
3
Register address Hi
4
Register address Low
5
Register number Hi
6
Register number Low
7
CRC error check Lo
8
CRC error check Hi
www.decode.rs
Content
x
6
x
x
x
x
x
x
Content
x
6
x
x
x
x
x
x
10/15
Modbus communication
EMU_UM_V12_05042020.pdf